SA-Profile: Automated Sulcus Angle Profiling from Super-Resolution MRI
Updated 51 min ago · first seen 11 Sept 2026
paper_01M294GN7FDKG92QY0S5AXHWP4
- Published
- 11 Sept 2026
- T1 · 51 min ago
- arXiv
- 2609.10125
- T1 · 51 min ago
- Category
- cs.CV
- T1 · 51 min ago
Abstract
Trochlear dysplasia (TD) is an abnormality of the femoral trochlea associated with anterior knee pain and patellar instability. The sulcus angle (SA) is used to assess trochlear morphology, but it is typically measured on a single axial MR slice with no clear guidance on which to select, making it sensitive to slice selection and landmark placement. We propose an automatic framework for continuous SA profiling from super-resolved MR volumes. Clinically acquired axial, coronal, and sagittal MR scans are combined using implicit neural representations to reconstruct a high-resolution volume. SA measurements are computed across the trochlear region using two landmark detection U-Net models. The approach was evaluated on the public fastMRI dataset and a small in-house cohort of patients with TD. Compared with conventional manual single-slice SA measurements, the proposed automated method yielded a mean absolute error of 11.6$^\circ$ while providing continuous characterization of trochlear morphology. Population-level analysis demonstrated distinct mean SA profiles between the public cohort and the in-house TD cohort, highlighting the potential of profile-based assessment to characterize TD. By reducing reliance on a single manually selected axial slice, the proposed framework extends conventional SA assessment to a continuous profile-based description of trochlear morphology without additional imaging, while remaining conceptually linked to current clinical assessment. Further validation is required. The code is available: https://github.com/wehrlimi/SA_Profile.
Authors 8
Michael Wehrli, Leo Widmer, Edwin Li, Noel Fiechter, Lorenzo Pettinari, Sidaty El Hadramy, Carol C. Hasler, Philippe C. Cattin
Specification
- Official page
Source:arXiv (Atom API + RSS)T1observed 51 min agohigh
- Arxiv announce type
- cross
Source:arXiv (Atom API + RSS)T1observed 51 min agohigh
- arXiv id
- 2609.10125
Source:arXiv (Atom API + RSS)T1observed 51 min agohigh
- Categories
- cs.CV, cs.AI
Source:arXiv (Atom API + RSS)T1observed 51 min agohigh
Source:arXiv (Atom API + RSS)T1observed 51 min agohigh
- Primary category
- cs.CV
Source:arXiv (Atom API + RSS)T1observed 51 min agohigh
- Published
- 11 Sept 2026
Source:arXiv (Atom API + RSS)T1observed 51 min agohigh
Each value shows its source, tier and observation time. Conflicting claims are kept side by side and flagged — never averaged. How AI Atlas records facts →
Provenance
Attributed facts
9
Source tiers
T19
Freshest observation
51 min ago
Conflicts
None
No models linked to this paper yet.
- Authors
- Michael Wehrli, Leo Widmer, Edwin Li
As of
Rewind the record: see this entity's attributes exactly as AI Atlas knew them on a given day.
Claim history
Official pageofficial_url1
| Value | Valid from → to | Status | Source | Confidence | Extractor |
|---|---|---|---|---|---|
| https://arxiv.org/abs/2609.10125 | → current | current | arXiv (Atom API + RSS)T1 | high | deterministic |
Abstractabstract1
| Value | Valid from → to | Status | Source | Confidence | Extractor |
|---|---|---|---|---|---|
| Trochlear dysplasia (TD) is an abnormality of the femoral trochlea associated with anterior knee pain and patellar instability. The sulcus angle (SA) is used to assess trochlear morphology, but it is typically measured on a single axial MR slice with no clear guidance on which to select, making it sensitive to slice selection and landmark placement. We propose an automatic framework for continuous SA profiling from super-resolved MR volumes. Clinically acquired axial, coronal, and sagittal MR scans are combined using implicit neural representations to reconstruct a high-resolution volume. SA measurements are computed across the trochlear region using two landmark detection U-Net models. The approach was evaluated on the public fastMRI dataset and a small in-house cohort of patients with TD. Compared with conventional manual single-slice SA measurements, the proposed automated method yielded a mean absolute error of 11.6$^\circ$ while providing continuous characterization of trochlear morphology. Population-level analysis demonstrated distinct mean SA profiles between the public cohort and the in-house TD cohort, highlighting the potential of profile-based assessment to characterize TD. By reducing reliance on a single manually selected axial slice, the proposed framework extends conventional SA assessment to a continuous profile-based description of trochlear morphology without additional imaging, while remaining conceptually linked to current clinical assessment. Further validation is required. The code is available: https://github.com/wehrlimi/SA_Profile. | → current | current | arXiv (Atom API + RSS)T1 | high | deterministic |
Arxiv announce typearxiv_announce_type1
| Value | Valid from → to | Status | Source | Confidence | Extractor |
|---|---|---|---|---|---|
| cross | → current | current | arXiv (Atom API + RSS)T1 | high | deterministic |
arXiv idarxiv_id1
| Value | Valid from → to | Status | Source | Confidence | Extractor |
|---|---|---|---|---|---|
| 2609.10125 | → current | current | arXiv (Atom API + RSS)T1 | high | deterministic |
Categoriescategories1
| Value | Valid from → to | Status | Source | Confidence | Extractor |
|---|---|---|---|---|---|
| cs.CV, cs.AI | → current | current | arXiv (Atom API + RSS)T1 | high | deterministic |
PDFpdf_url1
| Value | Valid from → to | Status | Source | Confidence | Extractor |
|---|---|---|---|---|---|
| https://arxiv.org/pdf/2609.10125 | → current | current | arXiv (Atom API + RSS)T1 | high | deterministic |
Primary categoryprimary_category1
| Value | Valid from → to | Status | Source | Confidence | Extractor |
|---|---|---|---|---|---|
| cs.CV | → current | current | arXiv (Atom API + RSS)T1 | high | deterministic |
Publishedpublished_at1
| Value | Valid from → to | Status | Source | Confidence | Extractor |
|---|---|---|---|---|---|
| 11 Sept 2026 | → current | current | arXiv (Atom API + RSS)T1 | high | deterministic |
Claims are temporal and append-only: a new observation closes the previous claim (valid_to) instead of overwriting it. Conflicting claims from different sources are kept side by side and flagged — never averaged. Methodology →
New paper: SA-Profile: Automated Sulcus Angle Profiling from Super-Resolution MRI
arxiv
| Source | Document | Type | Tier | Last observed | Snapshots |
|---|---|---|---|---|---|
| arXiv (Atom API + RSS) | rss.arxiv.org/rss/cs.AI | feed | T1· Official | 51 min ago | 1 |
Tier 1 = official/primary, 2 = quality secondary, 3 = community, 4 = unverified. Every snapshot is archived; see all sources and the methodology.