Abstract
This paper proposes a fully differentiable jitter correction method for X-ray phase-contrast micro computed tomography using a deep learning-based image quality metric that estimates and compensates per-projection rigid jitter directly from the acquired projection data, without a pre-scan motion-free reference. The approach builds on a gradient-based auto-focus strategy adapted to parallel-beam geometry. A set of candidate objective functions is benchmarked in a controlled study, and the sensitivity of the visual information fidelity (VIF) metric to the jitter artifact is verified with the target phase-contrast data. To operate without a clean reference, a compact 3D convolutional neural network is trained to predict the VIF score from a single corrupted volume. A spatially selective total variation penalty applied exclusively to the image background is introduced to penalize spurious high-frequency structures that otherwise emerge during optimization. Experiments on biological specimens acquired at different synchrotron beamlines are conducted. Evaluation uses jitter motion applied to simulated and experimentally acquired projection data. The result confirms that the integrated pipeline reliably recovers fine structural detail lost due to jitter, with generalization demonstrated across morphologically distinct samples.
Authors 9
Junan Chen, Yiting Jia, Joscha Maier, Dominik John, Sami Wirtensohn, Imke Greving, Silja Flenner, Matthias Wieczorek, Julia Herzen
Specification
- Official page
Source:arXiv (Atom API + RSS)T1observed 50 min agohigh
- Arxiv announce type
- replace
Source:arXiv (Atom API + RSS)T1observed 50 min agohigh
- arXiv id
- 2608.27034
Source:arXiv (Atom API + RSS)T1observed 50 min agohigh
- Categories
- cs.CV
Source:arXiv (Atom API + RSS)T1observed 50 min agohigh
Source:arXiv (Atom API + RSS)T1observed 50 min agohigh
- Primary category
- cs.CV
Source:arXiv (Atom API + RSS)T1observed 50 min agohigh
- Published
- 11 Sept 2026
Source:arXiv (Atom API + RSS)T1observed 50 min agohigh
Each value shows its source, tier and observation time. Conflicting claims are kept side by side and flagged — never averaged. How AI Atlas records facts →
Provenance
Attributed facts
9
Source tiers
T19
Freshest observation
50 min ago
Conflicts
None
No models linked to this paper yet.
- Authors
- Junan Chen, Yiting Jia, Joscha Maier
As of
Rewind the record: see this entity's attributes exactly as AI Atlas knew them on a given day.
Claim history
Official pageofficial_url1
| Value | Valid from → to | Status | Source | Confidence | Extractor |
|---|---|---|---|---|---|
| https://arxiv.org/abs/2608.27034 | → current | current | arXiv (Atom API + RSS)T1 | high | deterministic |
Abstractabstract1
| Value | Valid from → to | Status | Source | Confidence | Extractor |
|---|---|---|---|---|---|
| This paper proposes a fully differentiable jitter correction method for X-ray phase-contrast micro computed tomography using a deep learning-based image quality metric that estimates and compensates per-projection rigid jitter directly from the acquired projection data, without a pre-scan motion-free reference. The approach builds on a gradient-based auto-focus strategy adapted to parallel-beam geometry. A set of candidate objective functions is benchmarked in a controlled study, and the sensitivity of the visual information fidelity (VIF) metric to the jitter artifact is verified with the target phase-contrast data. To operate without a clean reference, a compact 3D convolutional neural network is trained to predict the VIF score from a single corrupted volume. A spatially selective total variation penalty applied exclusively to the image background is introduced to penalize spurious high-frequency structures that otherwise emerge during optimization. Experiments on biological specimens acquired at different synchrotron beamlines are conducted. Evaluation uses jitter motion applied to simulated and experimentally acquired projection data. The result confirms that the integrated pipeline reliably recovers fine structural detail lost due to jitter, with generalization demonstrated across morphologically distinct samples. | → current | current | arXiv (Atom API + RSS)T1 | high | deterministic |
Arxiv announce typearxiv_announce_type1
| Value | Valid from → to | Status | Source | Confidence | Extractor |
|---|---|---|---|---|---|
| replace | → current | current | arXiv (Atom API + RSS)T1 | high | deterministic |
arXiv idarxiv_id1
| Value | Valid from → to | Status | Source | Confidence | Extractor |
|---|---|---|---|---|---|
| 2608.27034 | → current | current | arXiv (Atom API + RSS)T1 | high | deterministic |
Categoriescategories1
| Value | Valid from → to | Status | Source | Confidence | Extractor |
|---|---|---|---|---|---|
| cs.CV | → current | current | arXiv (Atom API + RSS)T1 | high | deterministic |
PDFpdf_url1
| Value | Valid from → to | Status | Source | Confidence | Extractor |
|---|---|---|---|---|---|
| https://arxiv.org/pdf/2608.27034 | → current | current | arXiv (Atom API + RSS)T1 | high | deterministic |
Primary categoryprimary_category1
| Value | Valid from → to | Status | Source | Confidence | Extractor |
|---|---|---|---|---|---|
| cs.CV | → current | current | arXiv (Atom API + RSS)T1 | high | deterministic |
Publishedpublished_at1
| Value | Valid from → to | Status | Source | Confidence | Extractor |
|---|---|---|---|---|---|
| 11 Sept 2026 | → current | current | arXiv (Atom API + RSS)T1 | high | deterministic |
Claims are temporal and append-only: a new observation closes the previous claim (valid_to) instead of overwriting it. Conflicting claims from different sources are kept side by side and flagged — never averaged. Methodology →
- New paperPaperDifferentiable Jitter Correction using Deep Learning-based Image Quality Metric for Phase-Contrast Micro-CT
New paper: Differentiable Jitter Correction using Deep Learning-based Image Quality Metric for Phase-Contrast Micro-CT
arxiv
| Source | Document | Type | Tier | Last observed | Snapshots |
|---|---|---|---|---|---|
| arXiv (Atom API + RSS) | rss.arxiv.org/rss/cs.CV | feed | T1· Official | 50 min ago | 1 |
Tier 1 = official/primary, 2 = quality secondary, 3 = community, 4 = unverified. Every snapshot is archived; see all sources and the methodology.