Skip to content
AI Atlas
PaperActive

Reliability-Aware Hybrid-K Ensemble Selection for Cervical Cytology Classification: Integrating Discrimination, Calibration, and Selective Prediction

arxiv.org/abs/2609.09189

quality89

Updated 4 h ago · first seen 11 Sept 2026

paper_01M294GKQCZQC08TKPHFJ90K3V

Published
11 Sept 2026
T1 · 4 h ago
arXiv
2609.09189
T1 · 4 h ago
Category
eess.IV
T1 · 4 h ago

As of

Rewind the record: see this entity's attributes exactly as AI Atlas knew them on a given day.

Claim history · Abstract

1 claims · 1 propertiesShow all properties

Abstractabstract1

Claim history for Abstract
ValueValid from → toStatusSourceConfidenceExtractor
High classification accuracy alone is insufficient for clinical image analysis, where calibrated confidence and reliable uncertainty estimates are essential. This study proposes a reliability-aware Hybrid-K ensemble selection framework for multiclass cervical cytology classification using the SIPaKMeD dataset. Nine deep learning architectures were evaluated using a fixed stratified five-fold partition and three training seeds. After post-hoc temperature scaling, models were assessed using macro-F1, accuracy, AUROC, expected calibration error (ECE), worst-class ECE (WC-ECE), area under the risk-coverage curve (AURC), Brier score, and negative log-likelihood (NLL). Models were ranked using an equal-weight composite score, and Hybrid-K ensembles were formed from the top-ranked models using soft voting. Robustness was examined using 5,000 Dirichlet-sampled metric-weight vectors, leave-one-metric-out analysis, and corrected paired testing across 15 fold-by-seed evaluations. The final Hybrid-2 ensemble, comprising Swin-Tiny and TinyViT-5M, reduced AURC by 43%, NLL by 17%, and WC-ECE by 36% relative to the best individual model. It was selected in 96.8% of random weighting scenarios, remained unchanged across all leave-one-metric-out analyses, and improved the full composite score. However, per-metric gains were not statistically significant after Holm-Bonferroni correction (all adjusted p >= 0.168). Because post-hoc calibration did not use a fully independent calibration set, calibration-dependent results should be interpreted as exploratory internal estimates. Overall, the framework identified a compact ensemble robust to alternative metric weightings and improved reliability point estimates under internal validation on a single dataset.currentcurrentarXiv (Atom API + RSS)T1highdeterministic

Claims are temporal and append-only: a new observation closes the previous claim (valid_to) instead of overwriting it. Conflicting claims from different sources are kept side by side and flagged — never averaged. Methodology →