GRIPNet: Gaussian Radial Intensity Prior Guided Architecture for Pulmonary Nodule Detection in CT
Updated 2 h ago · first seen 11 Sept 2026
paper_01M294H20EQXQPNWHFFWS8BN38
- Published
- 11 Sept 2026
- T1 · 2 h ago
- arXiv
- 2609.11312
- T1 · 2 h ago
- Category
- cs.CV
- T1 · 2 h ago
Abstract
Lung cancer causes more deaths than any other malignancy, and low-dose CT screening is the main pathway to early diagnosis. That pathway hinges on the smallest lesions, yet nodules below six millimeters remain hard to detect, because most methods treat a nodule as a generic object and ignore the imaging physics behind its appearance. We show that this appearance is highly regular. Intensity peaks at the geometric center of a nodule and decays radially in a Gaussian pattern, and a fit to 18,218 annotated lesions from three public benchmarks yields a mean radial coefficient of determination above 0.86 in every dataset and size stratum. A square convolution samples both axes uniformly and is mismatched to this radial signal, most severely for small nodules. Guided by this evidence, we propose GRIPNet (Gaussian Radial Intensity Prior Network), a detector in which every module maps to a measurable property of the intensity distribution. Pinwheel convolutions decompose radial gradients, a dual-frequency module separates boundary detail from structural context, dilated masked attention matches the decay extent, and an adaptive loss reweights samples by conspicuity. GRIPNet raises mAP@0.5 to 95.3, 91.6 and 97.9 percent on KanserSet, LUNA16 and Lung-PET-CT-Dx while sharpening high-IoU localization at real-time speed.
Authors 2
Haojie Yang, Ran Su
Specification
- Official page
Source:arXiv (Atom API + RSS)T1observed 2 h agohigh
- Arxiv announce type
- new
Source:arXiv (Atom API + RSS)T1observed 2 h agohigh
- arXiv id
- 2609.11312
Source:arXiv (Atom API + RSS)T1observed 2 h agohigh
- Categories
- cs.CV, cs.AI
Source:arXiv (Atom API + RSS)T1observed 2 h agohigh
Source:arXiv (Atom API + RSS)T1observed 2 h agohigh
- Primary category
- cs.CV
Source:arXiv (Atom API + RSS)T1observed 2 h agohigh
- Published
- 11 Sept 2026
Source:arXiv (Atom API + RSS)T1observed 2 h agohigh
Each value shows its source, tier and observation time. Conflicting claims are kept side by side and flagged — never averaged. How AI Atlas records facts →
Provenance
Attributed facts
9
Source tiers
T19
Freshest observation
2 h ago
Conflicts
None
No models linked to this paper yet.
- Authors
- Haojie Yang, Ran Su
As of
Rewind the record: see this entity's attributes exactly as AI Atlas knew them on a given day.
Claim history · Categories
Categoriescategories1
| Value | Valid from → to | Status | Source | Confidence | Extractor |
|---|---|---|---|---|---|
| cs.CV, cs.AI | → current | current | arXiv (Atom API + RSS)T1 | high | deterministic |
Claims are temporal and append-only: a new observation closes the previous claim (valid_to) instead of overwriting it. Conflicting claims from different sources are kept side by side and flagged — never averaged. Methodology →
- New paperPaperGRIPNet: Gaussian Radial Intensity Prior Guided Architecture for Pulmonary Nodule Detection in CT
New paper: GRIPNet: Gaussian Radial Intensity Prior Guided Architecture for Pulmonary Nodule Detection in CT
arxiv
| Source | Document | Type | Tier | Last observed | Snapshots |
|---|---|---|---|---|---|
| arXiv (Atom API + RSS) | rss.arxiv.org/rss/cs.CV | feed | T1· Official | 2 h ago | 1 |
Tier 1 = official/primary, 2 = quality secondary, 3 = community, 4 = unverified. Every snapshot is archived; see all sources and the methodology.