Skip to content
AI Atlas
PaperActive

From Few-Shot Segmentation to Clinician-in-the-Loop Medical Image Analysis

arxiv.org/abs/2609.10001

quality89

Updated 2 h ago · first seen 11 Sept 2026

paper_01M294H3VX1VZ8X1AHYV7H28C8

Published
11 Sept 2026
T1 · 2 h ago
arXiv
2609.10001
T1 · 2 h ago
Category
cs.CV
T1 · 2 h ago

As of

Rewind the record: see this entity's attributes exactly as AI Atlas knew them on a given day.

Claim history · Abstract

1 claims · 1 propertiesShow all properties

Abstractabstract1

Claim history for Abstract
ValueValid from → toStatusSourceConfidenceExtractor
Few-shot medical image segmentation (FSMIS) seeks to delineate unseen structures from a small support set, but its standard formulation fixes task-defining evidence before inference. This assumption is fragile under acquisition shift, atypical pathology, ambiguous boundaries, and poor image quality. Adding clinician interaction and rapid adaptation is not sufficient: the binding constraint is deciding when asking or changing is warranted. We therefore reframe FSMIS as a three-layer sequential decision problem. First, decidable self-assessment separates errors that a bounded intervention can repair from those that no admissible intervention can reach. We formalize this distinction through a correctable set defined by the update operator and remaining interaction budget. Second, selective interaction allocates a distinct expert-attention budget by response-conditioned net expected value of information, yielding explicit accept, query, and defer actions. Third, bounded adaptation emphasizes reversibility and independent safety reassessment rather than speed. A complementary cross-case memory stores reproducible correction priors over failure modes instead of disease-specific mask priors. This structure links sparse support representation, cross-domain robustness, multi-level risk estimation, clinician feedback, and governed experience transfer. We state six hypotheses with an explicit dependency order and propose a minimal pilot that can falsify the foundational self-assessment claim before a clinician study. The central claim is not that interaction resolves domain shift, but that scarce expert attention should be used only when a bounded intervention is expected to reach a clinically better outcome.currentcurrentarXiv (Atom API + RSS)T1highdeterministic

Claims are temporal and append-only: a new observation closes the previous claim (valid_to) instead of overwriting it. Conflicting claims from different sources are kept side by side and flagged — never averaged. Methodology →