Skip to content
AI Atlas
PaperActive

A Comparative Evaluation of Pre-trained Convolutional Neural Networks for Melanoma Detection

arxiv.org/abs/2609.11550

quality89

Updated 2 h ago · first seen 11 Sept 2026

paper_01M294H29PESAZ8Y5G40DT3JXS

Published
11 Sept 2026
T1 · 2 h ago
arXiv
2609.11550
T1 · 2 h ago
Category
cs.CV
T1 · 2 h ago

As of

Rewind the record: see this entity's attributes exactly as AI Atlas knew them on a given day.

Claim history · Abstract

1 claims · 1 propertiesShow all properties

Abstractabstract1

Claim history for Abstract
ValueValid from → toStatusSourceConfidenceExtractor
Early diagnosis of melanoma is critical for improving patient survival rates. However, accurately distinguishing melanoma from other skin lesions remains a significant clinical challenge due to the high visual similarity among lesion types and variability in image acquisition conditions. Artificial intelligence, particularly machine learning, has emerged as a promising tool to support dermatological diagnosis by automating feature extraction from medical images. Among the available approaches, convolutional neural networks (CNNs) have demonstrated strong performance in image classification tasks, making them well-suited for analyzing both dermatoscopic and histopathological images, given their ability to capture hierarchical visual patterns relevant to lesion characterization. Nevertheless, despite numerous pre-trained CNN architectures having been proposed, selecting the most appropriate one for a given imaging modality remains an open challenge. In this study, we evaluate pre-trained convolutional neural networks (CNNs) for skin lesion classification using dermatoscopic and histopathological image datasets. Experiments were conducted on the HAM10000, ISIC 2018, and CR-AI4SkIN datasets, evaluating the ResNet50, VGG16, VGG19, MobileNet, and InceptionV3 architectures under the same training protocol. The experimental evaluation showed that the models achieved accuracies ranging from 71% (InceptionV3 on ISIC 2018) to 84% (ResNet50 on HAM10000) on dermatoscopic images. For histopathological images, accuracies ranged from 72% (VGG19) to 83% (ResNet50) on the CR-AI4SkIN dataset. The results demonstrate that model performance differs between dermatoscopic and histopathological image modalities, showing that architectures exhibiting similar performance on dermatoscopic images exhibit different performance on histopathological data.currentcurrentarXiv (Atom API + RSS)T1highdeterministic

Claims are temporal and append-only: a new observation closes the previous claim (valid_to) instead of overwriting it. Conflicting claims from different sources are kept side by side and flagged — never averaged. Methodology →